PCA 3

0024-8460

New product

PCA 3 model 225 is combustion and emissions analyzer. Measures and displays Flue Gas Oxygen, Carbon Monoxide, Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature and optionally measures and displays Nitric Oxide, Nitrogen Dioxide and Sulfur Dioxide. Simultaneously calculates and displays Combustion Eficiency, Excess Air, Carbon Dioxide, NOx and Oxygen reference values. 

More details

Add to wishlist

More info

PCA®3 is the new Bacharach's combustion and emissions analyzer, that enables fast and accurate measurement for on-demand or semi-continuous sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. PCA®3 is lightweight handleld combustion and emisions analyzer for service technicians and boiler contractors who need to determine combustion efficiency and perform emissions testing and ensure safe operating conditions. Directly measures and displays Flue Gas Oxygen (O2), Carbon Monoxide (CO), Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature and optionally measures and displays Nitric Oxide (NO), Nitrogen Dioxide (NO2) and Sulfur Dioxide (SO2). The PCA®3 simultaneously calculates and displays Combustion Efficiency (EFF), Excess Air (EA), Carbon Dioxide (CO2), NOx and Oxygen reference values. Additionally, the PCA®3 performs combustion calculations for ten different fuels and uses up to six field upgradable electrochemical sensors. Large, bright full-color graphic display, makes reading combustion and emissions test results in any work environment so easy as never before!

FEATURES:
• Uses up to 6 electrochemical sensors – field-upgradable
• Unique B-Smart® sensor technology saves downtime and calibration costs
• Measures and displays lue gas oxygen, carbon monoxide, stack temperature, combustion air temperature, draft and differential pressure
• Loss and eficiency are calculated from standard heat-loss calculations or using the Siegert formula for Europe
• Automatic CO over-range protection
• Ten different fuels – ability to load custom fuels
• Large full color graphic display with bright backlighting, zoom display and dimming mode 
• Multilingual display
• Sturdy metal gas and draft connectors

SPECIFICATIONS
Measurement Ranges:
Primary/Ambient Air Temperature: 20C to 537C
Stack Temperature: -20C to 1200C
Oxygen 0.1 to 20.9%
Carbon Monoxide (H2 Compensated): 0 to 4,000 ppm 
Carbon Monoxide (High Range): 4,001 to 20,000 ppm
Nitric Oxide: 0 to 3,000 ppm
Nitrogen Dioxide: 0 to 500 ppm
Sulfur Dioxide: 0 to 5,000 ppm
Pressure: +/- 179 mB
Calculated Ranges:
Combustion Eficiency: EFF 0.1 to 100.0% 
                               ETA 0.1 to 112.0% (Fuel Dependent)
Stack Loss: qA 0.1 to 100.0%
Excess Air: Lambda 1 to 9.55%
Carbon Dioxide: 0 to Fuel Dependent Maximum 
NOx (NO + NO2): 0 to 3500 ppm
NOx Referenced to %O2: 0 to 9999 ppm
CO Referenced to % O2: 0 to 9999 ppm
NO Referenced to % O2: 0 to 9999 ppm
NO2 Referenced to % O2: 0 to 9999 ppm
SO2 Referenced to % O2: 0 to 9999 ppm
CO/CO2: 0.0001 to Fuel Dependent Maximum
Selectable Fuels: Natural Gas, KOKS, LEG, Propane, Oil #2, Oil #6, Coal, BioFuel, LPG, Butane
Accuracy:
Stack Temperature; +/- 2C between 0 to 124C
                            +/- 3C between 125 to 249C
                            +/- 4C between 250 to 400C
Primary/Ambient Air Temperature: +/- 1C between 0 o to 100C
Pressure/Draft: +/- 0.05 mB between -2.49 to 2.49 mB 
                      +/- 2% Reading between – 24.9 to 24.9 mB
                      +/- 3% Reading between -100 to 100 mB
CO: +/- 5% of reading or 10 ppm in the range of 0 to 2000 ppm CO
       + 10% of reading in the range of 2001 to 4000 ppm
NO: +/- 5% of reading or 5 ppm whichever is greater in the range of 0 to 2000 ppm NO
NO2: +/- 5% of reading or 5 ppm whichever is greater 
SO2: +/- 5% of reading or 10 ppm whichever is greater in the range of 0 to 2000 ppm SO2
Dimensions: 22.9 cm x 7.6 cm x 6.3 cm
Weight: 0.6 kg (w/batteries)
Body Materials: Durable ABS Housing/Rugged Rubberized Over-molding and Protective Boot w/Magnet
User Interface: Full Color Graphic Display (320 x 240 pixels), Optional Infrared Printer
Operating Temperature Range: 0C to 40C
Operating Humidity Range: 15-90% RH Non-condensing
Power: 4 AA Alkaline Batteries, Optional Universal AC Adapter (100 to 240 Volts at 47 to 63 Hz)
Battery Life: Minimum of 10 Hours of Operation
Approvals: CE Mark EN 55011, EN 50270, CE Mark, EN 50379-2 

PCA®3 BASIC:
PCA®3 Combustion Analyzer, 12” Probe Assembly, Protective Boot w/Magnet, Fyrite® User Software, USB Cable, Replacement Filter Element (pkg. of 3), 4 ‘AA’ Alkaline Batteries and Hard Carrying Case.

ORDERING INFORMATION
0024-8460 PCA®3 225 (O2, CO)
0024-8461 PCA®3 235 (O2, CO, NO)
0024-8462 PCA®3 245 (O2, CO, CO high)
0024-8463 PCA®3 255 (O2, CO, SO2)
0024-8464 PCA®3 265 (O2, CO, NO, NO2)
0024-8465 PCA®3 275 (O2, CO, NO, SO2)
0024-8466 PCA®3 285 (O2, CO, NO, CO high)
0024-8467 PCA®3 225 Kit (O2, CO, printer)
0024-8468 PCA®3 235 Kit (O2, CO, NO, printer)
0024-8469 PCA®3 245 Kit (O2, CO, CO high, printer)
0024-8470 PCA®3 255 Kit (O2, CO, SO2, printer)
0024-8471 PCA®3 265 Kit (O2, CO, NO, NO2, printer)
0024-8472 PCA®3 275 Kit (O2, CO, NO, SO2, printer)
0024-8473 PCA®3 285 Kit (O2, CO, NO, CO high, printer)

REPLACEMENT PARTS AND ACCESSORIES
0024-1541 B-Smart® CO (H2 Compensated) Sensor
0024-1542 B-Smart® CO (high range) Sensor
0024-1545 B-Smart® NO Sensor
0024-1544 B-Smart® NO2 Sensor
0024-1543 B-Smart® SO2 Sensor
0024-0788 Replacement O2 Sensor
0024-0789 Replacement CO Sensor
0024-0881 Replacement NO Sensor
0024-0997 Replacement CO (high range)
0024-0998 Replacement SO2 Sensor
0024-1027 Replacement NO2 Sensor
0024-1400 IrDA Printer w/Disposable Batteries (comes with Reporting Pkg. Kit)
0024-1310 Printer Paper (5 rolls)
0006-8733 Printer Paper (1 roll)
0024-1254 Universal AC Power Adapter (110-240V)
0007-1644 Replacement Filter Element (pkg. of 3)
0024-7224 Compact Sample Conditioner*
0024-3004 Replacement Probe Assembly (North American)
0024-3053 Replacement Probe Assembly (European)
0024-1124 20 ft. Hose Extension with Sample, Draft and Thermocouple Lines
0024-1470 Fyrite® User Software
0021-7006 Tru Spot Smoke Tester 

All instruments can be upgraded to include combinations of CO (high), NO, NO2
and SO2
*The Compact Sample Conditioner is recommended when measuring NO2 and
SO2 to ensure the highest degree of measurement accuracy. 

Reviews

No customer reviews for the moment.

Write a review

PCA 3

PCA 3

PCA 3 model 225 is combustion and emissions analyzer. Measures and displays Flue Gas Oxygen, Carbon Monoxide, Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature and optionally measures and displays Nitric Oxide, Nitrogen Dioxide and Sulfur Dioxide. Simultaneously calculates and displays Combustion Eficiency, Excess Air, Carbon Dioxide, NOx and Oxygen reference values. 